9-3 A94F0TR
See FLOW CHART No.9 <P-ON+7V is not output.>
See FLOW CHAR
T No.9 <P-ON+7V is not ou
tput.>
AL+13V(M+13V) is not output.
FLOW CHART NO.12
Ye s
No
Is approximately +13V voltage supplied to the
cathode of D641 and D642?
Check C639, D
642 and their periphery circuit, and
service it if defective.
Check f
or short-circuiting or leak on the load circuit,
and service it if de
fective.
P-ON+5V is not output. (LCD+16V is outputted normally.)
FLOW CHART NO.10
Is approximately +6.8V voltage supplied to the
collector of Q643?
Is approximately +6V voltage supplied to the
base of Q641 and the b
ase of Q643?
No
Ye s
Ye s
Check D645 and their periphery circuit, and service
it if defective.
No
Replace Q641 and Q643.
P-ON+5V(TUNER+5V) is not output. (LCD+16V is outputted normally.)
FLOW CHART NO.11
Is approximately +6.7V voltage supplied to the
collector of Q640?
Is approximately +6V voltage supplied to the
base of Q641 and the base of Q643(Q640)?
No
Ye s
Ye s
Check D645 and their periphery circuit, and service
it if defective.
No
Replace Q641 and Q643(Q640).
D+5.5V is not output.
FLOW CHART NO.13
Is approximately +5V voltage supplied to the
cathode of D634?
Ye s
No
Check for short-circuiting or leak o
n the load circuit,
and service it if def
ective.
Check C634, D634 and their periphery circuit, and
service it if de
fective.
Commentaires sur ces manuels